INOGEN ONE G5 PRODUCT OVERVIEW Pdf Download (2024)

INOGEN ONE G5 PRODUCT OVERVIEW Pdf Download (1)
  1. Manuals
  2. Brands
  3. Inogen Manuals
  4. Oxygen Equipment
  5. One G5
  6. Product overview

Hide thumbs Also See for ONE G5:

  • User manual
  • ,
  • Technical manual (18 pages)
  • ,
  • Getting started manual (2 pages)
  • Bookmarks

Advertisement

Quick Links

Download this manual

INOGENONEG5

PRODUCTOVERVIEW

JulienGineste

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisement

INOGEN ONE G5 PRODUCT OVERVIEW Pdf Download (2)

Related Manuals for Inogen ONE G5

  • Medical Equipment Inogen One G5 User Manual

    (30 pages)

  • Medical Equipment Inogen One G5 Technical Manual

    (18 pages)

  • Medical Equipment Inogen One G5 Quick Manual

    Column change guide (2 pages)

  • Medical Equipment Inogen One G5 Getting Started Manual

    Connect app (2 pages)

  • Inogen One G5 Manual

    (article)

  • Oxygen Equipment Inogen One G3 User Manual

    Inogen one g3 oxygen concentrator user manual (46 pages)

  • Oxygen Equipment Inogen One G3 Getting Started

    (2 pages)

  • Oxygen Equipment Inogen One G3 Getting Started

    (3 pages)

  • Oxygen Equipment Inogen One G2 User Manual

    Oxygen concentrator (50 pages)

  • Oxygen Equipment Inogen One Technical Manual

    (33 pages)

  • Oxygen Equipment Inogen ONE G4 Technical Manual

    Oxygen concentrator (19 pages)

  • Oxygen Equipment Inogen GS-100 Technical Manual

    At home stationary oxygen concentrator (15 pages)

Summary of Contents for Inogen ONE G5

  • Page 1 INOGENONEG5 PRODUCTOVERVIEW JulienGineste...
  • Page 2 InogenOneG5Specifications Dimensions: L/W/H:7.19in./3.26in./7.11in. w/8‐cellbattery L/W/H:7.19in./3.26in./8.15in. w/16‐cellbattery L/W/H:7.19in./3.26in./9.03in. Weight: 4.7pounds(includessinglebattery) Noise: 38dBAatsetting2 MaximumSoundPowerof60dBAandMaximum SoundPressurelevelof50dBAperISO80601‐2‐69 Warmuptime: 2minutes OxygenConcentration**: 90%‐ 3%/+6%atallsettings FlowControlSettings: 6settings:1to6 MaximumOutletPressure <28.9PSI Power:ACPowerSupply: ACInput:100to240VAC 50to60Hz Auto‐Sensing:2.0‐1.0A DCPowerCable: DCInput:13.5‐15.0VDC RechargeableBattery: Voltage:12.0to16.8VDC(±0.5V) BatteryDuration*: Upto6.5hourswithsinglebattery Upto13hourswithdoublebattery BatteryChargingTime: Upto3hoursforasinglebattery Upto6hoursforadoublebattery EnvironmentalRangesIntendedforUse: Temperature:41to104˚F(5to40˚C) Humidity:0%to95%,non‐condensing Altitude:0to10,000ft(0to3048meters) EnvironmentalRangesIntendedfor...
  • Page 3 BluetoothAppCompatibility (Notavailableyet) • EMEAversionwillhaveBTdisabled. • InthefutureBTcanbeactivatedinanAuthorizedInogenServiceCenterwhen availableintheEMEAmarkets...
  • Page 4 G5SystemWeightandDimensions Configuration Alone With Bag Concentrator 1.61 3.55 1.95 4.30 Concentrator w/ 8-cell 2.15 4.74 2.49 5.48 Concentrator w/ 16-cell 2.60 5.73 2.93 6.47 8-cell battery 0.54 1.19 16-cell battery 0.99 2.18 0.34 0.74 Power Supply (with cord) 0.59 1.31 Length Width Height...
  • Page 5 G5PulseVolumesatFlowSettings SameasG3andG4butwithonemoresetting G5 Flow Setting Breaths per Minute mL/breath +/- 15% per ISO 80601-2-67 Total Volume per Minute (ml/min) 1050 1260...
  • Page 6 G5UserInterfacePanel • NewLargerDisplayScreen • DisplaysSymbolsandNumbersOnly • NoText (refertousermanualforallsymboldefinitions) FlowSettingControl Backlight Display Buttons AudibleAlert Button PowerOn/Off Aremovablestaticclinglabelis appliedoverthedisplayscreen withthetextbelow,please haveuserremoveuponsetup. VolumeControl Button Contains Transmitter Module IC: 2417C-BX31A AudibleSignals FCC ID: N7NBX31A This device complies with Part 15 of the IndicatorLights FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference...
  • Page 7 G5PowerSupplies BA‐501ACPowerSupply Input:100to240VAC,50to60Hz Auto‐sensing:2.0‐1.0Aforworldwide BA‐306DCPowerCable Input:13.5‐15.0VDC...
  • Page 8 G5PowerPort Powerportaccess...
  • Page 9 G5BatteryLocation Slidebatteryon Latchwillclickintoplacewhen thebatteryisinpositon...
  • Page 10 G5BatteryOptions Model#BA‐500 8CellBattery ~6.5HoursRunTime Model#BA‐516 16CellBattery ~13HoursRunTime BatteryIndicatorGauge...
  • Page 11 G5BatteryRunTimes Power Consumption 8-cell run time Power Consumption 16-cell run time (hours:minutes) (hours:minutes) Setting 1.0 14.6 6:35 14.8 13:28 Setting 2.0 18.7 5:03 18.4 10:22 Setting 3.0 26.9 3:27 26.7 7:01 Setting 4.0 37.8 2:25 37.4 4:55 Setting 5.0 48.5 1:51 48.4 3:48...
  • Page 12 G5BatteryChargeTimes 8-cell charge time 16-cell charge time (hours:minutes) (hours:minutes) Standby 2:46 3:48 Setting 1.0 2:49 3:53 Setting 2.0 2:47 3:53 Setting 3.0 2:46 3:50 Setting 4.0 2:45 3:49 Setting 5.0 2:43 4:43 Setting 6.0 3:09 5:40...
  • Page 13 AirIntakeandExhaustLocations IntakeVents GrossParticleFiltersshouldberemoved andcleanedweekly– #RP‐500 ExhaustVent...
  • Page 14 G5Columns #RP‐502 RemoveDust Capsbefore installing Accesscolumnsbyremovingbatteryand slidinglatch,openwireringandpullcolumns out. RemoveDust Capsbefore installing...
  • Page 15 InogenOneG5CarryBag Model#CA‐500 G5intakeandexhaustventsshouldbevisiblethroughmesh,on front,sidesandbottomofbag Paddedfootingisdesignedfor ExhaustVent IntakeVent IntakeVent usewithbothsingleand doublebattery.Bottommesh isintendedtoallowairflow forexhaustandbattery.
  • Page 16 InogenOneG5CarryBag Model#CA‐500continued Cutangleintopofbagfor properorientationof devicetoaccesscannula Velcrotopflap port Smallpocketwith toaccessdisplay Smallfront zipperclosure pouchforextra underfrontflap cannulatubing Pouchforinsertingonto luggagehandleorcart GrabHandle Perforatedmaterialatbackof bagtoallowforairflowto Cutoutforpower deviceandbattery portaccess...
  • Page 17 InogenOneG5CarryBag Model#CA‐500,CarryStrapDetails Carrystrapisadjustablefrom28”to53” Removableshoulderpad Includesaremoveableshoulderpadand swivelfasteners Swivelfasteners...
  • Page 18 OptionalAccessoryG5Backpack Model#CA‐550 Grabhandleorforhanging backpack Velcroloopstohold cannulatubing Frontpocket w/zipperedclosure Cutangleintopfrontof backpackforproper Clearplasticwindowto orientationofdeviceto viewdisplay accesscannulaport Sidepockets Adjustableflapclosureto accommodatesingleor doublebattery G5intakeandexhaustventsshouldbevisiblethroughmesh,on front,sidesandbottomfrontofbackpackforproperairflow...
  • Page 19 G5Backpackcontinued Insideview; twoback meshpockets, largeinside pocketand smallhookfor keys Paddedfor comfort Adjustableand removablechest strap7”to16” Bucklesforadjusting straps26”to58”...
  • Page 20 OptionalAccessory ExternalBatteryCharger Model#BA‐503 Whenthebatteryisinthecorrectposition,asolid redlightwillindicatethatthebatteryischarging. Whenthegreenlightilluminates,thebatteryis fullycharged....
  • Page 21 FAAClearance Thisstatementislocatedatthebottomofeachratingslabelthat isappliedtotheG5deviceandprovidesthenecessaryclearance forairlineonboarduse...
  • Page 22 InogenOneG5SystemIncludes: • InogenOneG5Concentrator • OneSingleBattery* • (1)NasalCannula(7ft.Softstyle) • CarryBag • ACPowerSupplyw/cable • DCPowerCable • UserManual • GettingStartedGuide • GettingStartedGuideBluetoothApp • WarrantyStatement(Invoicewillstatethespecificwarrantyperiod) *Variesbasedonpackagesold,refertoIS‐500‐XXfordetails.
  • Page 23 InogenOneG5SystemPackaging...
  • Page 24 PositioningoftheG5intheMarket InogenOne Caire PhilipsRespironics ResMed FreestyleComfort SimplyGoMini Mobi Single/InternalBatterySystemPrice $2,995 $2,695 $2,995 $2,295 Settings 1‐6pulse 1‐5pulse 1‐5pulse 1‐4pulse Weightw/singlebattery 4.7lbs 5lbs 5lbs 5.5lbsw/internalbattery Dimensionsw/singlebattery 7.19"x8.15”x3.26" 10"x7.3"x3.1" 9.4"x8.3"x3.6" 7.95"x9.6"x4.49" Soundatsetting2 38dBA 43dBA 42dBA 38dBA SingleBattery:Upto5hours SingleBattery:upto4hours SingleBattery:upto4.5hours InternalBattery:6hours BatteryDurationatsetting2 DoubleBattery:Upto10hours DoubleBattery:upto8hours DoubleBattery:upto9hours...
  • Page 25 TalkingPoints • LighterthanInogenOneG3. • QuieterthanInogenOneG3. • SmallerthanInogenOneG3. • OnemoresettingthanInogenOneG3. • Highestoxygenoutputperpoundofanyportableconcentrator clearedforuseintheU.S.homecaremarket.
  • Page 26 ComponentMaintenanceandReplacement Component Maintenance Replacement Filter Maintenance Gross particle filter Wash weekly Not required within 5 year life As needed indicated by alert prior to any Intake filter None performance degradation Output filter None Replace as needed As indicated by alert prior to performance Sieve bed maintenance None degradation...
  • Page 27 THANKYOU!
INOGEN ONE G5 PRODUCT OVERVIEW Pdf Download (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Merrill Bechtelar CPA

Last Updated:

Views: 6565

Rating: 5 / 5 (70 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Merrill Bechtelar CPA

Birthday: 1996-05-19

Address: Apt. 114 873 White Lodge, Libbyfurt, CA 93006

Phone: +5983010455207

Job: Legacy Representative

Hobby: Blacksmithing, Urban exploration, Sudoku, Slacklining, Creative writing, Community, Letterboxing

Introduction: My name is Merrill Bechtelar CPA, I am a clean, agreeable, glorious, magnificent, witty, enchanting, comfortable person who loves writing and wants to share my knowledge and understanding with you.